Bio-Threat Detection & Collection
IBAC 2

The IBAC 2 is a fully automated bio-detection sensor that can support continual, 24/7, air monitoring or can be set to targeting sampling windows to align to hours of operation. It alarms in less than 60 seconds when a bio-threat is present. IBAC can be configured to support automated aerosol sampling either in conjunction with its’ triggered alarms or at a set frequency sampling time. In wide service throughout the world, IBAC 2 is used to collect and detect aerosolized agents for all four classes of biological threats (spore, viral, cellular, and protein toxins) with low false alarm.

Early Warning of Bio-Aerosol Threats

REAL-TIME WARNING CAPABILITY

Autonomous 24/7 operation with no consumables. Detection algorithms for indoor and outdoor use.

ALARM AUTOMATICALLY TRIGGERS SAMPLE COLLECTION

System triggers collector only when high-probability of bio-agent threat, greatly reducing consumables and number of samples to process.

MOST WIDELY DEPLOYED BIOLOGICAL TRIGGER

Operates as part of a network configuration in "first tier" building protection system, or via battery for mobile detection capability.

Specifications
SYSTEM OVERVIEW
Data Storage Internal 2 GB MicroSD memory card; stores over 1 yr of data
Training Requirements < 2 hrs
Full specifications
ENVIRONMENTAL
Operating Humidity 5% to 95%, non-condensing
Operating Temperature -5 to 125 °F (-20 to 50 °C)
Storage Temperature -40 to 160 °F (-40 to 70 °C)
PHYSICAL FEATURES
Dimensions (L x W x H) 9.5 x 6.5 x 9.0 in (24.0 x 16.5 x 22.9 cm) - without battery; DFU Collector: 3.5 x 3 in (H x Diameter) 8.9 x 7.6 cm;
C100 Collector: 4.5 x 5.5 in (H x Diameter) 11.4 x 14 cm
Weight 7.5 lbs (3.4 kg); DFU Collector: 1.3 lbs (0.6 kg); C100 Collector: 3.0 lbs (1.4 kg)
Enclosure & Protection Aluminum, IP66 weatherproof
POWER
Battery Specs Li-ion BB 2590 military battery; up to 14 hrs runtime; charge < 4 hrs
Cold Start Time < 5 mins
Input Voltage 100-240 VAC (adapter supplied); 18-36 VDC
Power Consumption DFU Collector: 60 watts; C100 Collector: 60 watts
SAMPLING & ANALYSIS
Collection Media DFU Collector: Dry sampling - polyester felt filters (47mm diameter, 1 micron); C100 Collector:
Wet sampling - buffer rinse fluid provided in premeasured vials
Max Flow Rate DFU Collector: 100 L/min; C100 Collector: 200 L/min
Particle Size DFU Collector: 1 to 10 microns; C100 Collector: 1 to 10 microns
Sample Collection Integrated with DFU or C100 sample collector (see below)
Sample Introduction Airborne particles; triggered aerosol sample collector
Sample Phase Aerosol; flow rate 4.0 L/min (0.14 ft3 /min)
Sample Recovery DFU Collector: Particle extraction from filter performed in vial with liquid buffer; C100 Collector:
Manual liquid rinse performed at collector, yields 6mL of liquid
Sampling & Analysis Continuous sampling 24/7/365; indoor/outdoor alarm settings;
analysis time configurable down to 1 second
Sampling Method DFU Collector: Dry collection; C100 Collector: Wet or dry collection
Sensitivity < 100 particles/L of air
Threats Spores, vegetative bacteria, viruses, and toxins; particle size: 0.7 – 10 microns
SYSTEM INTERFACE
Communication Ethernet, RS-232; optional embedded wireless (900MHz or 2.4GHz)
Output Particle data, sensor diagnostics, bio-alarm, and fault
Display and Alerts On-board LED for visual indication; full display via software on external computer
TECHNOLOGY
Technology UV Laser Induced Fluorescence (LIF)

Related documents

Exports restrictions

The information contained in this page pertains to a dual use product controlled for export by the Export Administration Regulations (EAR). Diversion contrary to US law is prohibited. US Department of Commerce authorization is not required prior to export or transfer to foreign persons or parties unless otherwise prohibited.