The FLIR identiFINDER R500 is an extremely sensitive and accurate digital handheld gamma radionuclide identification device (RID). Available in two configurations (NaI and LaBr), the R500 quickly detects, locates, accurately measures, and identifies radiation sources. The additional detector volume allows it to identify radioactive material where other instruments cannot. When large areas need to be screened rapidly or there is potential for shielding, the identiFINDER R500 provides superior sensitivity and performance.
Determine Nuclide Identity in Seconds
ENHANCED SENSITIVITY
Reduced time to locate radioactive source; identification algorithm (ANSI N42.34 library) reduces false alarm and nuisance events
EASILY OPERATED
Common operating interface provides immediate comfort when using the device; spectroscopy knowledge not required for meaningful operation
LIMITED MAINTENANCE REQUIRED
Automatic calibration and continuous LED stabilization for temperature control and other conditional changes; 5-year factory maintenance interval
SYSTEM OVERVIEW |
|
---|---|
Data Storage | 2GB internalmemory; up to 600,000 spectra |
Training Requirements | <10minsfor operator; 1 dayfor advanced user |
ENVIRONMENTAL |
|
---|---|
Operating Humidity | 10 to 80% |
Operating Temperature | -4 to 122 °F(-20 to 50 °C) |
Storage Temperature | 14 to 95 °F(-10 to 35 °C) |
OTHER |
|
---|---|
Global Positionsing System [GPS] [removable] | 12-channel SiRFIII receiver |
PHYSICAL FEATURES |
|
---|---|
Dimensions (L x W x H) | 8.3 x 5.1 x 12.7 in (21.1 x 12.9 x 32.3 cm) -with battery |
Weight | ≤6.4 lbs(≤2.9 kg) |
POWER |
|
---|---|
Battery Specs | FLIR powerPACK ultra 2 (LSD NiMH, rechargeable); ≥8h operational batterylife; recharge ≤4hwhen using AC; recharge >4hwhen using USB |
Cold Start Time | <2 mins from cold start |
Input Voltage | 100-240 VAC (wall and car adapters and USB cable supplied) |
SAMPLING & ANALYSIS |
|
---|---|
Nuclide Identification | According to ANSI N42.34 |
Sample Introduction | Absorption of EM gamma or neutron emissions |
Sampling & Analysis | From a few seconds to minutes |
Threats | Detects neutron or gamma radiation emitted from natural occurrences in the environment, special nuclear material, industrial, or medical material |
SYSTEM INTERFACE |
|
---|---|
Communication | USB 2.0;mini-B socket; Bluetooth® Class 2.0, ≤10mrange |
Software | On-board webserver software |
TECHNOLOGY |
|
---|---|
Corrections | Real-time linearization of gamma spectrum |
Dose Range | 0 µSv- 1 Sv(0 µrem- 100 rem) |
Dose Rate & Accuracy (Cs-137) | 0.000 nSv/h – 1.00mSv/h (0 nrem/h – 100mrem/h)/ ±30 % |
Energy Range [Gamma] | 20 keV – 3 MeV |
Gamma [High Dose Rate] | Geiger-Müller |
Gamma LaBr3 | 1.5 x 1.5 in (38 x 38mm) |
Gamma Spectrum | 1024 channels; 3 MeV |
Geiger-Muller Dose Rate Range | 10 µSv/h - 1.0mSv/h (1.0mrem/h - 100mrem/h) |
Overload Dose Rate Range | 1mSv/h - 10mSv/h (100mrem/h - 1.0 rem/h) |
Scintillator Dose Rate Range | 0 nSv/h - 50 µSv/h (0 nrem/h - 5.0 mrem/h) |
Service Interval | 5 year factory maintenance |
Stabilization | Calibration source;LED |
Technology | Radioisotope identification device (RIID) |
Typical Resolution | 3.5% FWHM at 662 keV |