The FLIR identiFINDER S900 is an autonomous sensor that delivers real-time radiation detection and identification. It detects the presence or movement of radioactive material across borders, into buildings, at large public gatherings, and events. The S900 is available in a wide variety of form factors that can be tailored to application-specific environments and sensitivities. Deployment can begin with a standalone system and expand to a network of systems as needs change.
Autonomous, Real-Time Radiation Detection
RAPID, AUTONOMOUS MONITORING
Automatically analyzes collected data against extensive library when change in background radiation is detected. Radiation source is identified within seconds.
SCALABLE AND EXPANDABLE ARCHITECTURE
Detection units available in variety of sizes and housing and can be openly installed or concealed for high-consequence threat interdiction.
ADVANCED TEMPLATE MATCHING ALGORITHMS
Separates innocent material, such as medical patients, from threatening sources - a unique feature not offered by other area monitors.
SYSTEM OVERVIEW |
|
---|---|
Throughput | >100 kcps |
Training Requirements | <10 mins for operator; 1/2 day for advanced user |
Dose Rate/Accuracy | 50 keV – 1500 keV; ±30 % |
Scintillator Operating Range | 0 µSv/h – 100 Sv/h (0 rem/h – 10 mrem/h) |
Geiger-Muller Operating Range | 100 µSv/h – 10 mSv/h (10 mrem/h – 1.0 rem/h) |
ENVIRONMENTAL |
|
---|---|
Operating Humidity | 10 to 80%, non–condensing |
Operating Temperature | -4° to 122°F (-20° to 50°C) |
Storage Temperature | -22° to 158°F (-30° to 70°C) |
PHYSICAL FEATURES |
|
---|---|
Weight | 5.3 lb (2.4 kg) |
Enclosure & Protection | Aluminium, connection belt compatible with Tensabarrier and BelTrac; protection ratings IP54 |
Dimensions (H x Dia.) | 25.8 x 2.5 in (654 x 63 mm) |
POWER |
|
---|---|
Cold Start Time | 15 min |
Input Voltage | DC 12V, 3W, Power over Ethernet (PoE) |
SAMPLING & ANALYSIS |
|
---|---|
Sample Introduction | Absorption of EM gamma or neutron emissions |
Sampling & Analysis | From a few seconds to minutes |
Threats | Detects neutron or gamma radiation emitted from natural occurrences in the environment, special nuclear material, industrial, or medical material |
SYSTEM INTERFACE |
|
---|---|
Communication | Ethernet RJ45, 10 Mbit/s, 100 Mbit/s |
Display and Alerts | identiFINDER S900 Data Protocol for network integration |
TECHNOLOGY |
|
---|---|
Dose Rate Range | 0.01 µµSv/h – 1 Sv/h (1.0 µrem/h – 100 rem/h) |
Embedded Software | Windows® CE operating system |
Energy Range [Gamma] | 20 keV – 3 MeV |
Gamma [High Dose Rate] | Energy compensated Geiger Mller detector |
Gamma (NaI) | 2.0 x 3.0 in (51 x 76 mm) |
Gamma Spectrum | 1024 channels; 3 MeV |
Overload Threshold | 10 mSv/h – 1 Sv/h (1.0 rem/h – 100 rem/h) |
Service Interval | Recommended 2 year service interval |
Stabilization | K–40 calibration source and LED |
Technology | Autonomous radiation sensor |
Typical Resolution | ≤8 % FWHM at 662 keV |
Max Input Count Rate | 300 kcps |